| Availability: | |
|---|---|
| Quantity: | |
| PDF Export | |
P091
SiRON
8504401400
Order
| Model | Voltage | ||
| P091 | 24V |
Selection reference
| Model | Input voltage range | Power | Output voltage/current | Eificiency |
| P091-12V | 90-264VAC/ 127-370VDC | 120W | 12V/10A | 85% |
| P091-24V | 120W | 24V/5A | 88% | |
| P091-48V | 120W | 48V/2.5A | 89% |
Product Attributes
| Model | P091 | |
| @230VAC) Electric shock | Cold start, 40A | |
| Overcurrent Protection | range | 105 %lo - 150 %lo |
| type | Constant current mode, self-recovery is possible after abnormal load conditions are removed. | |
| Short circuit protection | Hiccup type, sustainable short circuit, self-healing | |
| Isolation withstand voltage | Input-output: 4kVAC,Input PE: 2 kVA C, Output PE: 0.5 kVA C(Test for 1 minute, leakage current <10mA) | |
| Operating temperature | -20℃to+60℃ | |
| performance | EMI | CISPR 32 / EN 55032 Class A; I E C / EN61000 -3 -3 |
| EMS | EC/EN 61000-4-2,Contac±4kv IEC/EN61000-4-310V/m, IEC/EN61000-4-610 Vr.m.s,IEC/EN61000-4-4,5,11 | |
| Safety standard | IEC/EN/UL62368、EN60335、GB4943 | |
| Shell material | Metal A L 1 1 0 0 , S GCC,Plastic (PC940 | |
| Wiring diameter | 26-10AWG | |
| Connector torque | Max 0.4N.m | |
| Rail type | TS35,The guide rail needs to be grounded. | |
| 3 5 × 1 2 5 × 1 1 2 . 7 | ||